• Skip to primary navigation
  • Skip to main content
  • Skip to footer
Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • Products
    • Automated Imaging Systems
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • Imaging Components
      • Motorized Stages
      • Focus Mechanisms
      • Laser Autofocus
      • Filter Wheels, Turrets & Shutters
      • Controllers & Joysticks
      • Robotic Sample Loaders
      • Physiology Platforms
      • Motorized Vertical Stages
    • Microscope Automation
      • Evident Olympus Microscope Automation
      • Nikon Microscope Automation
      • Leica Microscope Automation
      • Zeiss Microscope Automation
      • Automated Custom Imaging Systems
      • Other Microscope Brands
    • Nanopositioning Devices
    • Vibration Control
    • Custom Solutions & Contract Manufacturing
  • About
  • Applications
  • Blog
  • Contact Us
  • News
  • Technical Support
  • US Shop
  • United States
    • English
    • Deutsch
    • 简体中文
    • 日本語
  • Automated Imaging Systems
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • Imaging Components
    • Motorized Stages
    • Focus Mechanisms
    • Laser Autofocus
    • Filter Wheels, Turrets & Shutters
    • Controllers & Joysticks
    • Robotic Sample Loaders
    • Physiology Platforms
    • Motorized Vertical Stages
  • Microscope Automation
    • Evident Olympus Microscope Automation
    • Nikon Microscope Automation
    • Leica Microscope Automation
    • Zeiss Microscope Automation
    • Automated Custom Imaging Systems
    • Other Microscope Brands
  • Nanopositioning Devices
  • Vibration Control
  • Custom Solutions & Contract Manufacturing
Home » News » Introducing a new high-load Piezo wafer Z stage

Introducing a new high-load Piezo wafer Z stage

16.08.22

Queensgate, a brand of Prior Scientific, introduces a new high-load Piezo wafer Z stage

Queensgate’s wafer Z stage is a new addition to its product line, achieving fast response and settle times using Queensgate’s leading digital closed-loop controllers.

Queensgate, a brand of Prior Scientific, has announced the launch of the WP-Z-120A Wafer Stage. Millisecond response times and high bandwidth make the WP-Z-120A wafer positioning system ideal for applications where high throughput is essential. The Wafer Stage can be used in wafer inspection with an optical microscope such as the Prior Scientific OpenStand microscope or an OEM version using various optical or other inspection techniques.

The stage is designed to hold 300 mm (12″) wafers and delivers an exceptional performance with a load capacity of up to 8 kg, suitable for even very heavy wafer chucks. The stage incorporates capacitive positioning sensors to provide nanometer displacement measurement and precision closed-loop feedback. Flexure guidance offers friction-free, reliable motion to more than 120 µm in closed-loop mode and achieves fast response and settle times with Queensgate’s digital closed-loop controllers.

“We are pleased to introduce WP-Z-120A Wafer Scanner to the market. We wanted to design a wafer scanner that can carry a high load but achieves market-leading fast response and settle times,” said Alison Raby, Business Development Manager for Queensgate, “The Wafer Scanner was designed with OEM customers in mind and can be adapted to new custom versions easily.”

WP-Z-120A Wafer Stage can be customized for different environments and specifications. It is vacuum (HV) compatible and ideal for a chamber in an electron microscope. Ultra-high vacuum (UHV) and UHV-RAD radiation-hard versions are also available. A higher load custom version can be used for up to 14 kg loads and a tip-tilt version for platform leveling and scanning is available. An extended range of 160 μm and a smaller size for 200 mm wafers are possible upon request.

More News

New LED System for Fluorescence Microscopy

01.07.12

New LED System for Fluorescence Microscopy

Learn More

H101F Flat Top Stage

01.05.13

H101F Flat Top Stage

Learn More

Optimize Z Stack Image Acquisition Speed Using ProScan III TTL Breakout Box (H31TTLBB)

05.01.14

Optimize Z Stack Image Acquisition Speed Using ProScan III TTL Breakout Box (H31TTLBB)

Learn More

Introducing the LDB100F Brightfield LED Illumination System

14.02.14

Introducing the LDB100F Brightfield LED Illumination System

Learn More

Footer

Products

  • Automated Imaging Systems
  • Imaging Components
  • Microscope Automation
  • Nanopositioning Devices

Company

  • Custom Solutions & Contract Manufacturing
  • Applications
  • Technical Support
  • Careers

Resources

  • About
  • Blog
  • News
  • Contact Us

    Sign up to stay in the know...

    ✉

    Connect with us

    LinkedIn

    Prior Scientific Instruments Ltd.
    Units 3-4 Fielding Industrial Estate
    Wilbraham Road, Fulbourn
    Cambridge, CB21 5ET, UK

    inquiries@prior.com
    +44 (0)1223 881711

    Prior Scientific Inc.
    80 Reservoir Park Drive
    Rockland, MA. 02370
    U.S.A.

    info@prior.com
    +1 781 878 8442

    Prior Scientific Instruments GmbH
    Maria-Pawlowna-Str. 4
    07743 Jena
    Germany

    jena@prior.com
    +49 (0)3641 242 010

    Prior Scientific KK
    Kayabacho 3rd Nagaoka Bldg 10F,
    2-7-10, Nihonbashi Kayabacho
    Chuo-Ku, Tokyo 103-0025, Japan

    info-japan@prior.com
    +81 (0)3 5652 8831

    Prior Scientific Instruments (Suzhou) Ltd.
    Room 118, Meilihua Hemu Park,
    No. 393 Suhong Middle Road,
    Suzhou Industrial Park,
    Suzhou, 215000, China

    info-china@prior.com
    +86 (0)512 6617 5866

    Copyright © 2026 · Prior Scientific. Terms & Conditions | Privacy Policy | Impressum Site by Net Position Digital