• Skip to primary navigation
  • Skip to main content
  • Skip to footer
Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • 产品
    • 自动化成像系统
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • 成像组件
      • 电动显微镜平台
      • 生理学平台
      • 硬件激光自动对焦
      • 电动垂直载物台
      • 显微镜对焦机制
      • 机器人样本处理系统
      • 滤光片转盘和光阑
      • 显微镜控制器
    • 显微镜自动化
      • 用于Evident/奥林巴斯 (Olympus) 显微镜的自动化组件和配件
      • 用于尼康 (Nikon) 显微镜的自动化组件和配件
      • 徕卡 (Leica) 显微镜自动化
      • 用于蔡司 (Zeiss) 显微镜的自动化组件和配件
      • Prior Scientific的全自动化定制成像系统
      • Other Microscope Brands
    • 纳米定位
    • 振动控制
    • 定制解决方案和合同制造
  • 关于
  • 应用
  • 应用纪要
  • 联系我们
  • 新闻
  • 技术支持
  • 美国商店
  • 简体中文
    • English
    • Deutsch
    • 日本語
    • United States
  • 自动化成像系统
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • 成像组件
    • 电动显微镜平台
    • 显微镜对焦机制
    • 硬件激光自动对焦
    • 滤光片转盘和光阑
    • 显微镜控制器
    • 机器人样本处理系统
    • 生理学平台
    • 电动垂直载物台
  • 显微镜自动化
    • 用于Evident/奥林巴斯 (Olympus) 显微镜的自动化组件和配件
    • 用于尼康 (Nikon) 显微镜的自动化组件和配件
    • 徕卡 (Leica) 显微镜自动化
    • 用于蔡司 (Zeiss) 显微镜的自动化组件和配件
    • Prior Scientific的全自动化定制成像系统
    • Other Microscope Brands
  • 纳米定位
  • 振动控制
  • 定制解决方案和合同制造
Home » 应用纪要 » Leading Performance Nanopositioning for Microscopy | Prior Scientific

Leading Performance Nanopositioning for Microscopy | Prior Scientific

18.11.20

Queensgate: Leading Performance Nanopositioning for Microscopy

Queensgate, a brand of Prior Scientific, has a prolific 40-year history in the design of nanopositioning instruments and sensors, having supplied technology used in the manufacture of the majority of the world’s hard disks and on the international space station. Since joining the Prior Scientific group, they have turned part of their attention to the field of microscopy, and are now pleased to announce the launch of the OP400 objective positioner and NanoScan SP nanopositioning stage range.

The Best Step-Settle and Positioning Performance

High throughput screening and analysis are mainstays of biological and materials science imaging. For this reason, the OP400 and SP range are designed with speed in mind, offering rapid full-range travel alongside the fastest step-settle time available on the market. This means that long-distance z-stacking at high resolution has never been faster. High speed scanning can lead to oscillation, which in turn can lead to poor quality images and z-stacks, or even cause damage to the nanopositioning system. Queensgate products are designed to have high resonant frequency; combined with Queensgate’s proprietary digital control technology, this means that these systems can operate at best-in-class speeds without the risk of oscillation. Queengate’s expertise means that discarding images at the beginning of each stack due to system instability, or compromising on zstack acquisition speed, is no longer necessary.

NanoScan SP400/SP600

NanoScan SP400/SP600 Nanopositioning Piezo Sample Scanner

This speed does not compromise performance; the SP range has options with 400 nm and 600 nm range, which offer comparable or superior performance to shorter-range products in the same class. The OP400 has double the range of typical piezo-based objective positioners while still providing top-of-the-range linearity and repeatability.

NanoScan OP400

NanoScan OP400 Nanopositioning Piezo Objective Scanner

Both products perform in experiments demanding extremely high axial resolution, offering sub-nanometre resolution. Biological scientists can be confident that the mechanical resolution of their microscope z-axis will easily surpass the optical resolution of their imaging technique. Morphological changes as low as 0.7 nm can be detected or imaged, depending on the analysis method, making it ideal for surface examination of semiconductor or metallurgical samples. All this is made possible by integrated ultrasensitive capacitive sensors, which offer the highest positioning sensitivity irrespective of movement speed or system temperature.

Easy Integration for Accessible Experimental Success

Despite their market-leading performance, and perhaps unusually for such high precision equipment, there is little requirement for the user to calibrate these nanopositioning devices relative to other components of their system. The highest speed settings are compatible with any objective up to 500 g, with a second calibration set on offer for specialist objectives. Queensgate’s NPC controller range does the rest. This means that any user can be sure that Queensgate will be able to supply a product fit for their experimental needs that is ready to go straight out of the box.

Not only OP400 and SP-range are easy to set up, but they are compatible with a wide range of microscopes. The OP400 can be adapted to fit microscope nosepieces and objectives of any thread size, including 32 mm widefield systems. The full NanoScan SP-range is compatible with all Prior Scientific inverted stepper and linear motor stages, as well as motorized stages from Nikon, Olympus, and other major microscope manufacturers, and incubators from Tokai Hit and Okolabs. Furthermore, these systems can be used to enhance Prior’s already extremely rapid PureFocus 850 hardware autofocus, offering ±50 nm focus stability during long-duration time-lapse experiments.

With all these features combined, the OP400 and NanoScan SP-range provide nanopositioning solutions across the full spectrum of microscopy applications. The OP400 is well suited for applications requiring absolute sample stability, such as electrophysiology, super-resolution, or topography measurements. The NanoScan SP-range can enhance cell screening systems by allowing faster and more efficient collation of 3-dimensional data in conjunction with confocal, deconvolution, or super-resolution imaging techniques.

A Queensgate piezo objective positioner and piezo sample positioner against a textured blue background.

更多 应用纪要

Close up of a motorized xy stage on an OpenStand-V inverted imaging platform. imaging platform 27.07.26

显微镜与精密定位术语表 术语 : 定义及行业指南

了解更多
H100A compact precision motorized XY stage for upright microscopes 16.06.26

ProScan H100A紧凑型电动XY显微镜载物台 —— 精密显微成像专用产品经理问答

了解更多
Three quarters view of the Prior motorized filter cube turret for multi-colour fluorescence imaging. 13.05.26

电动滤光块转轮如何提升高级成像工作流中的显微镜性能

了解更多
HF108B滤光转轮:适用于自动化显微镜系统的高速荧光成像 21.04.26

HF108B滤光转轮:适用于自动化显微镜系统的高速荧光成像

了解更多

Footer

  • 自动化成像系统
  • 成像组件
  • 显微镜自动化
  • 纳米定位

  • 定制解决方案和合同制造
  • 应用
  • 技术支持
  • Prior Scientific的职业机会

  • 关于
  • 应用纪要
  • 新闻
  • 联系我们

    Sign up to stay in the know...

    ✉

    与我们联系

    Prior Scientific Instruments Ltd.
    Units 3-4 Fielding Industrial Estate
    Wilbraham Road, Fulbourn
    Cambridge, CB21 5ET, UK

    inquiries@prior.com
    +44 (0)1223 881711

    Prior Scientific Inc.
    80 Reservoir Park Drive
    Rockland, MA. 02370
    U.S.A.

    info@prior.com
    +1 781 878 8442

    Prior Scientific Instruments GmbH
    Maria-Pawlowna-Str. 4
    07743 Jena
    Germany

    jena@prior.com
    +49 (0)3641 242 010

    Prior Scientific KK
    Kayabacho 3rd Nagaoka Bldg 10F,
    2-7-10, Nihonbashi Kayabacho
    Chuo-Ku, Tokyo 103-0025, Japan

    info-japan@prior.com
    +81 (0)3 5652 8831

    Prior Scientific Instruments (Suzhou) Ltd.
    Room 118, Meilihua Hemu Park,
    No. 393 Suhong Middle Road,
    Suzhou Industrial Park,
    Suzhou, 215000, China

    info-china@prior.com
    +86 (0)512 6617 5866

    Copyright © 2026 · Prior Scientific. 条款及细则 | Privacy Policy | Impressum

    Manage Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    Functional Always active
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
    Preferences
    The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
    Statistics
    The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
    Marketing
    The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
    • Manage options
    • Manage services
    • Manage {vendor_count} vendors
    • Read more about these purposes
    View preferences
    • {title}
    • {title}
    • {title}