• Skip to primary navigation
  • Skip to main content
  • Skip to footer
Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • Products
    • Automated Imaging Systems
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • Imaging Components
      • Motorized Stages
      • Focus Mechanisms
      • Laser Autofocus
      • Filter Wheels, Turrets & Shutters
      • Controllers & Joysticks
      • Robotic Sample Loaders
      • Physiology Platforms
      • Motorized Vertical Stages
    • Microscope Automation
      • Evident Olympus Microscope Automation
      • Nikon Microscope Automation
      • Leica Microscope Automation
      • Zeiss Microscope Automation
      • Automated Custom Imaging Systems
      • Other Microscope Brands
    • Nanopositioning Devices
    • Vibration Control
    • Custom Solutions & Contract Manufacturing
  • About
  • Applications
  • Blog
  • Contact Us
  • News
  • Technical Support
  • US Shop
  • United States
    • English
    • Deutsch
    • 日本語
    • 简体中文
  • Automated Imaging Systems
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • Imaging Components
    • Motorized Stages
    • Focus Mechanisms
    • Laser Autofocus
    • Filter Wheels, Turrets & Shutters
    • Controllers & Joysticks
    • Robotic Sample Loaders
    • Physiology Platforms
    • Motorized Vertical Stages
  • Microscope Automation
    • Evident Olympus Microscope Automation
    • Nikon Microscope Automation
    • Leica Microscope Automation
    • Zeiss Microscope Automation
    • Automated Custom Imaging Systems
    • Other Microscope Brands
  • Nanopositioning Devices
  • Vibration Control
  • Custom Solutions & Contract Manufacturing
Home » Blog » Automated microscope image acquisition

Automated microscope image acquisition

15.05.23

 

Simple, open-source software solution for advanced imaging cells

Not every laboratory or research project is fortunate enough to be gifted large budgets, grants or funding. For many scientists and laboratory technicians this can make it difficult to develop advanced automated microscope and image acquisition systems, which are both cost-effective and capable of delivering the quality of results necessary to meet the demands of each research project. In practice, what often happens – especially where budgets are tight – is that the various parts required to construct and control an automated microscope system are sourced from different manufacturers or assembled from a combination of newly purchased and existing components. A typical system may, for example, include a microscope from one of the leading manufacturers, around which an image acquisition system is constructed. A system can be constructed from multiple suppliers with equipment such as automated multi-axes (x/y/z) stages, light source, motorized filter wheels, shutters, camera and mirrors. The challenge can be to develop control software that is capable of seeing the assembly as an integrated and coherent system, so that the potential from each component part can be fully exploited to produce high-quality, repeatable, and accurate images. This is especially true where researchers need to carry out complex imaging procedures, such as capturing images from specimens at multiple wavelengths. Of course, software is available from the leading microscope manufacturers. These products are, however, proprietary and often lack the necessary drivers or functionality to interface and control dissimilar motion and imaging devices from other suppliers. Even where options are available they can be expensive and require dedicated technical support. This is where open-source control and image acquisition software, such as Micro-Manager (µManager), and image analysis software, such as ImageJ, come into play.

Open source image acquisition software

µManager and ImageJ were developed specifically to allow research scientists and laboratory technicians to build sophisticated control software for microscope automation and image acquisition and analysis systems. µManager is compatible with Windows, Linux and Mac operating systems, with straightforward scripting and dynamic programming languages that make it quick and simple to create independent hardware interfaces for microscope, camera and automation devices, and then subsequently to modify, update or expand these as components are added or changed. µManager has in-built functionality for most common laboratory imaging tasks, while novel imaging procedures, extended functionality and specialized imaging applications can easily be developed. These can, for example, include time-lapse, multi-channel, z-stacks, and fast streaming, with ImageJ then providing seamless integration for detailed image analysis. Programmatic interfaces can also be added for third-party products, such as Matlab. Both µManager and ImageJ are widely supported by the scientific and academic community, and by our dedicated in-house team of specialists.

Driving down the cost of laboratory image acquisition

At Prior Scientific we invest considerable time and resource into product development, with the goal of making our microscope automation and nanopositioning systems as easy to use as possible, while delivering the highest standards of precision, repeatability, and reliability. A key aspect is our focus on the development of controllers and interface devices that ensure straightforward integration with most commonly used imaging software. This includes µManager. Ultimately, the benefit of µManager and ImageJ is their ability to help you reduce the cost of developing sophisticated microscope automation and image acquisition and analysis systems. Just as importantly, the simplicity, ease of programming, and functionality of these products enable you to minimize costs without sacrificing image resolution, speed and complexity of movement, system reliability, and repeatability, or the quality of your research work.

Discuss your application needs

To learn more contact our technical sales team today. Find out more about our software partners.

 

A monitor displaying microscope imaging software. A Prior OpenStand modular microscope is in the background.

More Blogs

Close up of a motorized xy stage on an OpenStand-V inverted imaging platform. imaging platform 27.07.26

Microscopy and Precision Positioning Glossary: Terms, Definitions and Industry Guide

Learn More
H100A compact precision motorized XY stage for upright microscopes 15.06.26

H100A Compact Motorized XY Microscope Stage for Precision Microscopy: Product Manager Q&A

Learn More
Three quarters view of the Prior motorized filter cube turret for multi-colour fluorescence imaging. 13.05.26

How a motorized filter cube turret expands microscope performance across advanced imaging workflows

Learn More
HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems 21.04.26

HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems

Learn More

Footer

Products

  • Automated Imaging Systems
  • Imaging Components
  • Microscope Automation
  • Nanopositioning Devices

Company

  • Custom Solutions & Contract Manufacturing
  • Applications
  • Technical Support
  • Careers

Resources

  • About
  • Blog
  • News
  • Contact Us

    Sign up to stay in the know...

    ✉

    Connect with us

    Prior Scientific Instruments Ltd.
    Units 3-4 Fielding Industrial Estate
    Wilbraham Road, Fulbourn
    Cambridge, CB21 5ET, UK

    inquiries@prior.com
    +44 (0)1223 881711

    Prior Scientific Inc.
    80 Reservoir Park Drive
    Rockland, MA. 02370
    U.S.A.

    info@prior.com
    +1 781 878 8442

    Prior Scientific Instruments GmbH
    Maria-Pawlowna-Str. 4
    07743 Jena
    Germany

    jena@prior.com
    +49 (0)3641 242 010

    Prior Scientific KK
    Kayabacho 3rd Nagaoka Bldg 10F,
    2-7-10, Nihonbashi Kayabacho
    Chuo-Ku, Tokyo 103-0025, Japan

    info-japan@prior.com
    +81 (0)3 5652 8831

    Prior Scientific Instruments (Suzhou) Ltd.
    Room 118, Meilihua Hemu Park,
    No. 393 Suhong Middle Road,
    Suzhou Industrial Park,
    Suzhou, 215000, China

    info-china@prior.com
    +86 (0)512 6617 5866

    Copyright © 2026 · Prior Scientific. Terms & Conditions | Privacy Policy | Impressum

    Manage Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    Functional Always active
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
    Preferences
    The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
    Statistics
    The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
    Marketing
    The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
    • Manage options
    • Manage services
    • Manage {vendor_count} vendors
    • Read more about these purposes
    View preferences
    • {title}
    • {title}
    • {title}