Prior Scientific

Prior Scientific

Experts in Precision Positioning and Microscope Automation

  • Products
    • Automated Imaging Systems
      • OpenStand-U
      • OpenStand-M
      • OpenStand-L
      • OpenStand-V
    • Imaging Components
      • Motorized Stages
      • Focus Mechanisms
      • Laser Autofocus
      • Filter Wheels, Turrets & Shutters
      • Controllers & Joysticks
      • Robotic Sample Loaders
      • Physiology Platforms
      • Motorized Vertical Stages
    • Microscope Automation
      • Evident Olympus Microscope Automation
      • Nikon Microscope Automation
      • Leica Microscope Automation
      • Zeiss Microscope Automation
      • Automated Custom Imaging Systems
      • Other Microscope Brands
    • Nanopositioning Devices
    • Vibration Control
    • Custom Solutions & Contract Manufacturing
  • About
  • Applications
  • Blog
  • Contact Us
  • News
  • Technical Support
  • US Shop
  • United States
    • English
    • Deutsch
    • 日本語
    • 简体中文
  • Automated Imaging Systems
    • OpenStand-L
    • OpenStand-M
    • OpenStand-U
    • OpenStand-V
  • Imaging Components
    • Motorized Stages
    • Focus Mechanisms
    • Laser Autofocus
    • Filter Wheels, Turrets & Shutters
    • Controllers & Joysticks
    • Robotic Sample Loaders
    • Physiology Platforms
    • Motorized Vertical Stages
  • Microscope Automation
    • Evident Olympus Microscope Automation
    • Nikon Microscope Automation
    • Leica Microscope Automation
    • Zeiss Microscope Automation
    • Automated Custom Imaging Systems
    • Other Microscope Brands
  • Nanopositioning Devices
  • Vibration Control
  • Custom Solutions & Contract Manufacturing
Home » Blog » Resonant frequency and nanopositioning

Resonant frequency and nanopositioning

24.03.23

 

How resonant frequency defines nanopositioning stage performance

It’s commonly believed that if you know the resonant frequency of a nanopositioning stage, then you’ll have an accurate indication of its performance, especially its dynamic performance. In simple terms, a higher resonant frequency is taken to equate with faster movement of each stage axis. Unfortunately, like many things in life, it’s rarely that simple! In practice, resonant frequency is determined by several factors. These will all affect the performance of the stage, and therefore need to be considered equally before the correct selection of a nanopositioning system can be made. These factors include:

  • The materials that are used to construct the stage, as material stiffness and density will affect resonant frequency. A low density material has a higher resonant frequency as its moving mass is low; however, if you add a load then the resonant frequency will drop quickly. By comparison, a stage with high stiffness, even if it is manufactured from a heavy material, will maintain its resonant frequency much better.
  • The load applied to the nanopositioning stage, which defines the loaded resonant frequency and is normally specified as the first resonance for each axis
  • The control and feedback electronics, which are crucial for controlling factors such as the effect of first and second resonance on the dynamic position of each stage axis
  • The overall system, including the stage with all its mounting accessories or flexures, and the device to which the stage is mounted, as each component may have a different resonant frequency.

The design of nanopositioning stages

From the brief list above it will be clear why simply considering the resonant frequency of each axis fails to provide an accurate picture of the performance of the nanopositioning system. It also explains why, in many instances, it is essential to customise each system to meet the specific requirements of individual applications.

For example, the materials of construction and design of the stage must be chosen to match the appropriate resonant frequency characteristics for each application. A key factor in this calculation will be the applied load. This is why we often focus on loaded performance on many of our datasheets as this criterion better reflects the practical use of the stage. In general terms, the greater the load acting on the stage the lower the resonant frequency of the stage will become. Our high stage stiffness means resonant frequency changes less with load change and therefore any dynamic tuning is less sensitive to load change.

Digital control

Advanced digital control of each nanopositioning stage is crucial. In particular, it allows the performance characteristics of the system to be precisely tuned for speed, resolution and payload, while eliminating any unwanted resonant frequency effects. We achieve this using a combination of customised software algorithms and notch filters; the latter allow us to attenuate signals within a narrowly defined band of frequencies. We can therefore minimise the effects of frequencies that occur close to the resonant frequency, effectively reducing the impact that first and second frequencies have on dynamic positioning. We also have a tool-box of algorithm modules to optimise stage performance. Velocity and acceleration control algorithms allow our stages to be driven at much higher operational bandwidths than devices that rely solely on position control. Although the latter uses a PID to control position, it cannot provide sufficient accuracy for control of high speed motion. In a situation where control within a move is required for producing accurate waveforms or ramps, the greater control is required. Trajectory control allows each stage axis to move rapidly to an exact position of within a few nanometres, without causing the stage to resonate. With these control methods a bandwidth of greater than 50% of the resonant frequency is possible, compared with just around 10% with a classic PID control. Additionally, we have recently introduced a resonance detection system on many of our nanopositioning stages, which protects each system from potential damage by shutting it down immediately a stage axis begins to resonate.

Making the right choice

Our electronic nanopositioning controllers are designed to match the exact characteristics of our different stage mechanisms and actuators, to ensure the highest standards of accuracy, repeatability and reliability. The multi-channel NPC-D-6000, for example, is capable of controlling up to three piezo actuators and two- or three-axis nanopositioning devices, with picometre levels of positioning resolution. Alternatively, our NPC-D-5200 series of closed loop controllers for piezo actuators are ideal for optimising the performance of high-speed stages, with each controller automatically calculating up to 120,000 positional readings from the stage every second. Selecting the best combination of nanopositioning stage and control technology for your particular application is not always straightforward. As we have indicted above, there are different factors that need to be considered, of which resonant frequency is just one; hysteresis, settling time, slew and non-linearity are among others that need to be considered. Together, they can all affect the performance, resolution and repeatability of each stage – and thus the quality of the scientific work for which the microscope unit is being used. This is why it is important to choose a system that has been developed specifically for your application and to partner with a manufacturer that has the knowledge, experience and resources to guide you towards the best choice. Prior Scientific has been involved in precision engineering for over 100 years, with over 40 years’ experience in Queensgate Nanopositioning (1978). We have the research, manufacturing capabilities and the products – both standard and custom engineered – to offer you the widest possible range of options, and then to provide you and your team with dedicated technical and commercial support.

Discuss your application needs

Contact our technical sales team to learn more.

 

An operator's blue-gloved hands hold a Queensgate piezo nanopositioning stage on a grey mat.

More Blogs

Close up of a motorized xy stage on an OpenStand-V inverted imaging platform. imaging platform 27.07.26

Microscopy and Precision Positioning Glossary: Terms, Definitions and Industry Guide

Learn More
H100A compact precision motorized XY stage for upright microscopes 15.06.26

H100A Compact Motorized XY Microscope Stage for Precision Microscopy: Product Manager Q&A

Learn More
Three quarters view of the Prior motorized filter cube turret for multi-colour fluorescence imaging. 13.05.26

How a motorized filter cube turret expands microscope performance across advanced imaging workflows

Learn More
HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems 21.04.26

HF108B Filter Wheel: High‑Speed Fluorescence Imaging for Automated Microscopy Systems

Learn More

Footer

Products

  • Automated Imaging Systems
  • Imaging Components
  • Microscope Automation
  • Nanopositioning Devices

Company

  • Custom Solutions & Contract Manufacturing
  • Applications
  • Technical Support
  • Careers

Resources

  • About
  • Blog
  • News
  • Contact Us

    Sign up to stay in the know...

    ✉

    Connect with us

    Prior Scientific Instruments Ltd.
    Units 3-4 Fielding Industrial Estate
    Wilbraham Road, Fulbourn
    Cambridge, CB21 5ET, UK

    inquiries@prior.com
    +44 (0)1223 881711

    Prior Scientific Inc.
    80 Reservoir Park Drive
    Rockland, MA. 02370
    U.S.A.

    info@prior.com
    +1 781 878 8442

    Prior Scientific Instruments GmbH
    Maria-Pawlowna-Str. 4
    07743 Jena
    Germany

    jena@prior.com
    +49 (0)3641 242 010

    Prior Scientific KK
    Kayabacho 3rd Nagaoka Bldg 10F,
    2-7-10, Nihonbashi Kayabacho
    Chuo-Ku, Tokyo 103-0025, Japan

    info-japan@prior.com
    +81 (0)3 5652 8831

    Prior Scientific Instruments (Suzhou) Ltd.
    Room 118, Meilihua Hemu Park,
    No. 393 Suhong Middle Road,
    Suzhou Industrial Park,
    Suzhou, 215000, China

    info-china@prior.com
    +86 (0)512 6617 5866

    Copyright © 2026 · Prior Scientific. Terms & Conditions | Privacy Policy | Impressum

    Manage Consent
    To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
    Functional Always active
    The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
    Preferences
    The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
    Statistics
    The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
    Marketing
    The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
    • Manage options
    • Manage services
    • Manage {vendor_count} vendors
    • Read more about these purposes
    View preferences
    • {title}
    • {title}
    • {title}